Indian Journal of Obstetrics and Gynecology Research

Print ISSN: 2394-2746

Online ISSN: 2394-2754

CODEN : IJOGCS

Indian Journal of Obstetrics and Gynecology Research (IJOGR) open access, peer-reviewed quarterly journal publishing since 2014 and is published under auspices of the Innovative Education and Scientific Research Foundation (IESRF), aim to uplift researchers, scholars, academicians, and professionals in all academic and scientific disciplines. IESRF is dedicated to the transfer of technology and research by publishing scientific journals, research content, providing professional’s membership, and conducting conferences, seminars, and award more...

Article type

Case Report


Article page

401- 403


Authors Details

M. P Kinker*, Abhilasha Kinker


Article Metrics


View Article As

 


Downlaod Files

   






Article statistics

Viewed: 733

PDF Downloaded: 490


Misplaced IUCD


Case Report

Author Details : M. P Kinker*, Abhilasha Kinker

Volume : 8, Issue : 3, Year : 2021

Article Page : 401-403

https://doi.org/10.18231/j.ijogr.2021.081



Suggest article by email

Get Permission

Abstract

The intra uterine device (IUD) is a popular family planning method worldwide. Some of the complications associated with the insertion of an IUD are well described in the literature. The frequency of IUD perforation is estimated to be between 0.05 & 1B per 1000 insertions. There are many reports of migrated intrauterine devices, but for fewer reports of IUDs which have penetrated into the rectum. Among the options available the multi-year cost of the copper T380A. IUD makes it one of the most cost-effective contraceptive options available. According to the World Health Organization Medical Eligibility Criteria, an IUCD can be inserted in the 48 hours postpartum, referred to here as Postpartum IUCD (PPIUCD), or after four weeks following a birth. With increased use of intra-uterine devices (IUDs) for contraception, an increase in the number of related problems are reported. A frequent clinical problem is the loss of filament at the external cervical os, the ‘lost tail’. The disappearance of the string or marker heralds potential problems such as retracted or turn off tail, misplacement within the cavity, intra-mural penetration or extra-uterine location.


Keywords: intrauterine device (IUD), Diagnostic laparoscopy.


How to cite : Kinker M P, Kinker A, Misplaced IUCD. Indian J Obstet Gynecol Res 2021;8(3):401-403

This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.