Indian Journal of Obstetrics and Gynecology Research (IJOGR) open access, peer-reviewed quarterly journal publishing since 2014 and is published under auspices of the Innovative Education and Scientific Research Foundation (IESRF), aim to uplift researchers, scholars, academicians, and professionals in all academic and scientific disciplines. IESRF is dedicated to the transfer of technology and research by publishing scientific journals, research content, providing professional’s membership, and conducting conferences, seminars, and award more...Original Article
Author Details :
Volume : 6, Issue : 3, Year : 2019
Article Page : 302-307
https://doi.org/10.18231/j.ijogr.2019.068
Abstract
Objective: Knowing that there is a wide variation in pelvic anatomy worldwide, it was an instinctive
query that whether radiotherapy planning in cancer cervix by four field box technique based on GOG
(gynaecologic oncology group) defined field carries adequacy and justification in our region. A prospective
trial was conducted at a Regional Cancer Centre located in Northern India, from August 2014 to July 2015.
CECT (contrast enhanced computed tomography) abdomen and pelvis was done in newly diagnosed 64
patients of cervical cancer with stage IB to IIIB. Using vessels as surrogates for lymph nodes, adequacy of
radiation portals using bony landmarks defined by GOG were assessed.
Materials and Methods: 2D (two dimensional) radiation portals were designed on conventional simulator
”Acuity” as per GOG recommendations. CECT pelvis from L1(first lumbar) to mid femur was done in
the same position along with same immobilization accessories used during conventional simulation. Three
parameters D1, D2 and D3 were defined for adequacy of superior, lateral, and anterior portals respectively.
Results: Increasing the length of AP:PA portal cranially by 4.5 cm will cover the proximal common iliac
nodes adequately. The width of the AP: PA portal needs to be increased by 3.6 cm to cover the distal
external iliac nodes adequately.
Conclusions: Conventional pelvic fields failed to cover all of pelvic lymph nodes in majority of this study
population. Diagnostic CT and MRI are suggested to be referenced to plan pelvic fields precisely when CT
simulation is not available.
Keywords: Cancer cervix, Conventional simulator, Bony landmarks.
How to cite : Tuli D, Thakur P, Gupta M, Seam R K, Gupta M, Evaluation of adequacy of conventional radiotherapy fields based on bony landmarks in cervical cancer patients using contrast enhanced computed tomography scan- A regional cancer centre experience. Indian J Obstet Gynecol Res 2019;6(3):302-307
This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.