Indian Journal of Obstetrics and Gynecology Research (IJOGR) open access, peer-reviewed quarterly journal publishing since 2014 and is published under auspices of the Innovative Education and Scientific Research Foundation (IESRF), aim to uplift researchers, scholars, academicians, and professionals in all academic and scientific disciplines. IESRF is dedicated to the transfer of technology and research by publishing scientific journals, research content, providing professional’s membership, and conducting conferences, seminars, and award more...

  • Article highlights
  • Article tables
  • Article images

Article statistics

Viewed: 2637

PDF Downloaded: 2901


Get Permission Sehrawat and Panchanadikar: Johnson’s formula to compare fetal weight with actual birth weight


Introduction

Precise fetal weight assessment is a problem which is associated where resources are low or subject to availability, especially in developing country like ours where major population still resides in rural area. From a multifactorial perspective the analysis of birth weight must be recognised.1 Antenatal care aims on identifying large and small gestational age fetuses, since they are always at the perinatal mortality or morbidity risk. By decreasing the complications linked to the birth or excessively large or small foetus that needs precise weight estimation of the foetus prior to the delivery decision.2 Restricted growth of both the intrauterine as well as macrosomia benefits the foetuses through evaluating the weight which could also diminish the risk of complications during maternal and neonatal.3 With small foetuses, foetal demise, birth asphyxia, neonatal hypothermia and hypoglycaemia and meconium aspiration all are increased not only due to the small size, the organs of the foetus but also functions sub-maturely.4 In childhood there is a subtle impairment in cognitive performance and educational performance reported in these children.5 Complications spanning up to long durations also includes high risk of stroke, dyslipidaemia, Type II diabetes mellitus, hypertension, or coronary heart diseases. Chronic lung disease or bronchopulmonary dysplasia is also more common in IUGR infants. IUGR also has direct effect on developing kidneys.6 Macrosomic foetuses suffer many complications linked to the delivery during birth that is comprised of intra‐partum asphyxia, bony injuries, brachial plexus injuries, shoulder dystocia, and other maternal issues like postpartum haemorrhage, pelvic floor injuries, or birth canal injuries.7 The cephalopelvic disproportion occurrence is highly frequent due to the increasing foetus size and also is a contributing factor for caesarean delivery or operative vaginal when opposed to the normal weighing foetuses. Macrosomic or LGA foetus pose a complication for both mother as well as themselves. Mainly 2 usual methods of birth weight estimation are: clinical palpation and sonographic evaluation.8 By the abdominal palpation the fetal weight estimation (by means of Leopold’s maneuvers) is personal and thus difficult for young physicians.9 Whereas, for the fetal weight estimation by clinical approach using fundal height are the easy objective along with.9

For the fetal weight estimation numerous clinical formulas like Johnson’s formula and Dawns, Dare’s, Risanto’s formula have been used. Moreover, one of the approaches is there for the measurement of SFH which has now found to be prevalent for the fetal weight estimation by means of the Johnson’s Formula since it is inexpensive and readily available with the help of nonelastic measuring tape. Though sonography is accurate, it is costly and entails to have special skill as used in terms of a screening tool for the detection of abnormal growth but since in our nation most of the population is rural oriented therefore women from poor resource settings lack access to reliable method of fetal weight estimation because of lack of sonography techniques. Pregnancies with lower risk a recommendation is made regarding the SFH: Symphysio-Fundal Height measurement which is a screening tool, used at initial levels and is not much expensive.10, 11, 12

Thus, Clinical efficacy in partaking a usual minimal cost, for the term birth weight prediction a non-invasive method in direction to recognize irregular growth along with to diminish the adverse perinatal outcome risk.

So, the present study aim was to regulate the fetal weight precision by means of Johnson’s formula and comparing it as per the definite birth weight.

Materials and Methods

The study of present prospective analytical has been supported by “the Department of Obstetrics and Gynaecology of tertiary care hospital in Pune. Study included a total of 500 pregnant women attending the OPD with full term pregnancy till onset of labour, fulfilling the inclusion criteria.

Inclusion criteria

  1. Pregnancy with singleton fetus

  2. Vertex presentation

Exclusion criteria

  1. Patients with sonographically diagnosed IUGR

  2. Pregnancy with complicated chronic disease

  3. Pregnancy with diagnosed oligohydramnios and polyhydroamnios

  4. Pregnancy with Intra uterine death

  5. Pregnancy with uterine or abdominal mass

  6. By the pre-eclampsia/eclampsia, HELLP syndrome no earlier pregnancy have been affected

  7. Patients with LMP not known or unsure of LMP or patients with lactational conception

Methodology

In the following ways the data for the given study has been attained:

  1. By detailed clinical history, abdominal and pelvic examination

  2. By fundal height measurement and station identification

  3. By fetal weight calculation using Johnson’s clinical formula

  4. By measuring outcome (weight of fetus

Fundal height measurement

Firstly, patient need to empty their bladder also by means of non - elastic, a flexible, standard sewing measuring tape in centimetres symphysio fundal height has been measured. For the measurement’s patient have to lie flat over her back by letting her legs extended. The measurement of the fundal height has been from center of the pubic symphysis upper border to the uterine fundus peak point.

Station Identification

A technique having “five-level is utilized for station designation. When doing a vaginal observation, probably the lowermost part of the” existing fetal component is actually over the ischial spines level. It's specified as actually set at 0 (zero) “station. Levels over the spines are actually specified in centimetre using stations of negative values, -2, -1, -3. Levels beneath the spines are actually specified in positive value, +1, +2, +3 facilities, right downcast to the pelvic floor.

Johnsons formula

Fetal weight in grams = (symphysio fundal height in cm – X) *155

Where,

X=13, when presenting part is not engaged

X= 12, when presenting part is at station 0

X= 11, when presenting part is at station” +113

Fetal Outcome (weight in grams)

In the delivery room the actual weight has been retrieved either delivered normally or if delivered by cesarean section, in operation theatre. As per the scale which was properly balanced the baby has been placed unclothed in the centre of it. In grams the weight has been verified.

Data analysis

In terms of mean (±SD), frequencies (in numeral cases) along with appropriate percentages of the data has been defined statistically. The Pearson correlation was used to test the level of correlation amid of the weight estimation by Johnson’s formulae and actual weight. For the efficacy evaluation the Linear Regression analysis has been carried out as per the Johnson’s formulae as a birth weight predictor. As per the statistically substantial probability value (p value) minimal to 0.05 has been measured. Using the computer programs all the statistical calculations has been done“ SPSS (Statistical Package for the Social Science; SPSS Inc., Chicago, IL, USA) version 21 and Microsoft Excel 2007” (Microsoft Corporation, NY, USA).

Results

Mean birth weight as prophesied through clinical (Johnson’s formulae) subsequently the actual birth weight was 3.13 Kg and 2.89 Kg correspondingly (Table 1, Table 2). Johnson’s formulae’s co-relates well with actual birth weight (r-0.86; 95% CI: 0.84-0.88), though prediction of fetal weight was slightly on a higher side. The least correlation was reported in cases with weight <2.5 kg (r-0.36; 95% CI: 0.14-0.55) (Table 3). Between the clinical as well as the actual birth weight the mean variance was an overestimation of 0.234 Kg i.e. an error of 8.1%. In 60.8% cases the difference was within range of 10% and in 84.8% the difference was less than 15%. In 94% of the cases the difference in weight estimation was less than 500 grams. The mean difference in estimation was highest in the babies having low birth weight i.e. <2.5 Kg. The mean difference in weight categories was 441 grams in <2.5 kg, 236 grams in 2.5-3 kg, 236 grams in 3-3.5 kg and 269 grams in > 3.5 Kg group (Table 4, Table 5).

Table 1

Mean weight by Johnson’s formulae and actual birth weight

Group SD Mean Mean difference % age diff
Birth Weight 500 0.38 2.895 0.23(0.19-0.28 8.1%
Johnson Formulae 500 0.344 3.1

Table 2

Birth weight distribution by actual birth weight and Johnson’s formulae

Actual Weight Johnson's Weight
BW %
<2 2 0 0.0%
2-2.5 74 3 0.6%
2.5-3 223 224 44.8%
3-3.5 174 180 36.0%
> 3.5 27 93 18.6%
Total 500 500 100.0%

Table 3

Correlation between Johnson’s formulae and actual birth weight

Group r- value 95% CI
2 - 2.5 0.36 0.14-0.55
2.5 - 3 0.56 0.46-0.64
3 - 3.5 0.66 0.56-0.73
> 3.5 0.36 -0.67
Total 0.86 0.84-0.88

Table 4

Absolute error in Johnson’s formulae for prediction of actual birth weight

Absolute error (gms)
< 0.15 87
0.15 - 0.25 148
0.25 - 0.35 146
0.35 - 0.50 89
>0.50 30
Total 500

Table 5

Percentage error in Johnson’s formulae for prediction of actual birth weight

Percentage error categories
< 5 97
5-10 207
10-15 120
15 - 20 42
20 - 25 19
25 - 30 5
30 - 40 10
Total 500

Discussion

To estimate weight of the fetal this is a routine obstetric practice through measuring the height of symphysio-fundal on every antenatal call along with to discuss on for a sonographic valuation if it fluctuates from the usual range to the evolution.

In the clinical practice the fetal weight estimation is rarely done by abdomen palpation. As we have derived to heavily depend on frequently readily accessible ultrasonography.14

As per the initial expectation of this method to provide standard for the objective to identify the abnormal size foetuses for evolutional age that has been currently destabilized through the prospective studies. It represented that for predicting the foetal weight clinical palpation is better than that of the sonographic estimates.15, 16, 17, 18

In comparison to an assessed single examination the evaluation viewed that different biometric of obstetric sonographic foetal might be superior and has found to be helpful.15, 19 Numerous well-known technical limitations are there for analysing foetal weight using sonographic technique. Amongst these given are as oligohydramnios, “maternal obesity, and anterior placentation. There are other drawbacks of ultrasonography that is equally complicated as well as labour intensive, being limited” as in potential manner by foetal structure’s suboptimal consideration. Expensive specially trained personnel along with the sonographic equipment is also required by this. Although in developed countries such costly imaging equipment is extensively available, is generally “this is not the terms in developing nations alike ours where the scarce of medical resources” exists.19, 20

As per the numerous approaches of the estimation of fetal weight, different results were noticed for the accuracy estimation. Humphries et al. presented the birth weight estimation accuracies, with both clinical as well as ultrasound, were still moderately low.21 Some studies of the EFW presented the ultrasound has been the finest EFW method, particularly in preterm fetuses,22, 23, 24 but further studies had not determined any difference amid of the given methods.25, 26, 27, 28

At term other studies have been conveyed imperfect precision of ultrasound EFW, mainly in macrosomic fetuses.23, 29 Baum et al. at term determined that no benefit ultrasound offered over clinical approximations of fetal weight.26 Equally validation is viewed for the Clinical estimation, especially for realistic in the light of the requirement, attainable standards. Differing outcomes have been seen about the precision of the numerous techniques of fetal bodyweight estimation. It was demonstrated that the birth weight judgement accuracies, mutually clinical as well as ultrasound, were so far impartially small Humphries et al.21

Specific tests presented the ultrasound was the best ways for EFW, especially in preterm fetuses22, 24 although other scientific tests did not conclude a little difference between the possibilities.25, 28 Especially in macrosomic fetuses numerous other researches has been renowned limited accuracy of ultrasound EFW in term.23, 29 It was determined that over clinical estimates ultrasound provided absolutely zero benefit at phrase of fetal weight Baum et al.26 For practical Clinical estimates should be perceived as likewise legitimate, specifically in the demand lighting, possible standards.

Clinically various calculations and formulae (Johnson’s, Dawn’s, Dare’s and Risanto’s formula) based on the measurement of uterine fundal height over symphysis pubis was been created. Moreover, SFH measurement came as from the different methods that now seem as popular for the fetal weight estimation using Johnson’s Formula since it is inexpensive and readily available with the help of non-elastic measuring tape.

In present study, we thus aimed at the comparison of expected fetal weight as per the actual birth weight by assessing symphysio-fundal height in antenatal women with >37weeks pregnancy by using Johnson’s formula. By clinical (Johnson’s formulae) “the mean birth weight is to be prophesied and actual birth weight” was 3.13 Kg and 2.89 Kg correspondingly.

Our study findings are as per the analysis of Shittu et al.,30 where the mean of birth weight as prophesied through Clinical method was 3.29 while the mean actual birth weight remained 3.25 Kg. In a similar study Siddiqua S et al.,31 observed the weight by clinical method as 3.59 kg while the definite birth weight remained 3.22 Kg. Bhandary A et al.32 in their study also observed mean birth weight with clinical method as 3.11 and actual birth weight as 2.99 Kg. Pravin Z et al.33 in a similar study in Bangladesh mean birth weight as prophesied by clinical (Johnson’s formulae) as well as the actual birth weight as 3.08 Kg and 2.99 Kg respectively.

In present study, on correlation analysis, Johnson’s formulae’s co-relates well with actual birth weight (r-0.86; 95% CI: 0.84-0.88), though prediction of fetal weight was slightly on a higher side. The least correlation was reported in cases with weight <2.5 kg (r-0.36; 95% CI: 0.14-0.55).

In a similar study by Shittu AS et al.,30 also observed excellent correlation (r-0.78; p<0.01) with most accurate results in birthweight’s middle range (2,500-<4,000 gm). The correlation coefficient of clinical estimation in present study is also differentiable as that of Dare et al. (r-0.74; p<0.01) in an analogous population.34 Correlation analysis amid “of the fetal weight and the actual birth weight” (Johnson's Formula) by Pravin et al.,33 knowingly discovered that the correlation of the“ actual birth weight with fetal weight (found by Johnson's Formula).” However, the correlation was weak for babies less than 2.5 Kg and more than 4.0 kg. Joshi et al.35 in their study also observed strong positive correlation “(p<0.001) between actual birth weight in comparison to the clinical” approach.

In addition, Stanislaw and Nahum discovered which the usage of ultrasonography had mostly no more precise compared to estimation that's based exclusively on quantitative evaluation of maternal as well as the pregnancy certain qualities.28 Chauhan et al,36 in the comparability of theirs of precision of the two techniques, observed absolutely no advantage in acquiring a sonographic estimation, since the accuracy of it is no superior to that of the clinical approach.

In present study, the mean variance between clinical as well as the actual birth weight remained an overestimation of 0.234 Kg i.e. an error of 8.1%. In 60.8% cases the difference was within range of 10% and in 84.8% the difference was less than 15%. In 94% of the cases the difference in weight estimation was less than 500 gms. The mean difference in estimation was highest in babies having “low birth weight i.e. <2.5 Kg.” The mean difference in weight categories was 441 grams in <2.5 kg, 236 grams in 2.5-3 kg, 236 grams in 3-3.5 kg and 269 grams in > 3.5 Kg group.

Shittu et al.30 also observed that, in their study set, the actual birthweight is clinically overestimated systematically used method (+) 400 gm. Bhandary Amritha et al.32 found the average error of (+) 120 gm by clinical method. In a study by Siddiqua et al.,31 the average error of (+) 343 gm.37 In the study, Tiwari and Sood38 presented an average error of (+) 327.3 gm by clinical method.

Sherman et al. conveyed“ that the estimation rates of within 10% of birth weight as 72% by clinical method.23 Shittu et al. stated that within 10% of birth weight rates of estimates as 70% by clinical method.30 However, in <2.5 Kg weight category this estimate fell to only 41.7%. Regardless of the variations in review design, the results are actually in consonance with individuals described by others that the precision of clinical opinion of birthweight is great. The experiments “by Hendrix et al. as well as Raman et al. proved that clinical opinion was” much high precise compared to sonographic estimate.29, 39 Sherman et al.23 and Titapantet al.17 in their studies observed that ultrasonic estimate is much more precise only in terms of low birthweight. Amid of the two methods no substantial variance was observed even at extremes of birthweight at term Watson et al.40 The primary issue associated to the computation of calculated fetal “weight by Johnson's Formula was, it” wasn't meaningfully precise babies having low birth weight. Furthermore, the end result suggested that calculated the weight of the fetal by adopting Johnson's Formula had an inclination in the direction of birth weight estimation, particularly in low birth weight cases. However, the difference was less than 10% in majority of the cases.

Conclusion

The observation means there's clearly a contribution for clinical of birthweight estimation as a device of analysis, signifying that clinical estimation is actually adequate to handle delivery and labour for a phrase pregnancy. Even in macrosomic foetus weight estimation for decision making concerning towards labour trials, no benefit appears to be there for gaining a regular sonographic birthweight. The role of estimation in the ultrasonographic seems that, when clinically it was estimated as the proposes weight is less “than <2,500 g, right after sonographic estimation may deliver a much better prediction as well as would be” additionally essential to evaluate these kinds of foetuses for congenital malformation as well as to complete the biophysical profile to figure out as the foetus well-being. The above-mentioned observations have crucial inference for developing nations such as ours in which there's absence “of technologically-advanced ultrasound devices capable of performing advanced capabilities such as for instance foetal weight but has a faced clinician” that might conduct the functionality likewise properly.

Source of Funding

None.

Conflict of Interest

None.

References

1 

M S Kramer Determinants of low birth weight: methodological assessment and meta-analysisBull World Health Organ198765566337

2 

R M Patterson T J Prihoda C E Gibbs R C Wood Analysis of birth weight percentile as a predictor of perinatal outcomeObstet Gynecol19866845963

3 

C Alessandra Z Margherita B Silvia C Diana C Garbriella D Natalia Symphysio funal height at term: A new birth weight predictive equationInt J Nurs Midwifrey2013561136

4 

J M Piper E Xenakis E M J M McFarland B D Elliot M D Berkus O Larger Do growth retarded premature infants have different rates of perinatal morbidity and mortality than appropriate grown premature infants? Obstet Gynecol1996872169740029-7844Ovid Technologies (Wolters Kluwer Health)

5 

M J Hernandez Moreno Vargas Garcia C Vera Gasper D Casanova Alvarez N Manzanilla Sevilla R; Evaluation of the clinical method of johnson and Toshach for calculating fetal weightGinecolObstet Mex198553335637637

6 

R W Johnson Calculations in estimating fetal weightAm J Obstet Gynecol195774929

7 

James J. Nocon Debra K. McKenzie Lisa J. Thomas Richard S. Hansell Shoulder dystocia: An analysis of risks and obstetric maneuversAm J Obstet Gynecol19931686173270002-9378Elsevier BV

8 

H. E. Onah A. C. C. Ikeme P. O. Nkwo Correlation between Intrapartum Fundal Height and Birth WeightAfr J Reprod Health200262231118-4841JSTOR

9 

Robert W. Johnson Clarence E. Toshach Correlation between intrapartum fundal height and birth weightAm J Obstet Gynecol195468389160002-9378Elsevier BV

10 

10.American college of obstetricians and gynaecologists. acog practice bulletin no. 134:fetal growth restrictionObstet Gynecol2013112233

11 

French College of obstetricians and gynaecologistsJ Gynecol Obstet Biol Reprod201342101825

12 

The investigation and management of the small-for-gestational age fetus. Royal College pf Obstericians and Gynaecologists2013

13 

K R Niswander V J Caparo Van coevering RJ; estimation of birth weight by qualify ed external uterine measurementsObstet Gynecol197036294302

14 

S P Chauhan D Cowan E F Magann T H Bradford W E Roberts J C Morrison Intrapartum detection of a macrosomicfetus: clinical versus and sonographic modelsAust N Z J Obstet Gynaecol199535326670

15 

T Ratanasiri S Jirapornkul W Sombooporn K Seejorn P Patumnakul Comparison of the accuracy of ultrasonic fetal weight estimation by using the various equationsJ Med Assoc Thai2002859627

16 

W S Bossak W N Spellacy Accuracy of estimating fetal weight by abdominal palpationJ Reprod Med197295860

17 

V Titapant S Chawanpaiboon K Mingmitpatanakul A comparison of clinical and ultrasound estimation of fetal weightJ Med Assoc Thai20018412517

18 

J S Abramowicz D M Sherer E Bar-Tov J R Woods Jr The cheek-to-cheek diameter in ultrasonographic assessment of fetal growthAm J Obstet Gynecol199116584652

19 

D A Nzeh S Rimmer W M O Moore L Hunt Prediction of birthweight by fetal ultrasound biometryBr J Radiol19926577998790007-1285, 1748-880XBritish Institute of Radiology

20 

Aboulfazl Mehdizadeh Reza Alaghehbandan M.D.,and Hayedeh Horsan Comparison of clinical versus ultrasound estimation of fetal weightAm J Perinatol2000 17 0523360735-1631, 1098-8785Georg Thieme Verlag KG

21 

S P Chauhan T C Lutton K J Bailey J C Morrison Intrapartum prediction of birth weight: clinical versus sonographic estimation based on femur length aloneObstet Gynecol19938156957

22 

S P Chauhan P M Lutton K J Bailey J P Guerrieri J C Morrison Intrapartum clinical, sonographic and parous patients’ estimates of newborn birth weightObstet Gynecol1992799568

23 

D Sherman S Arieli J Tovbin G Siegel E Caspi I Bukovsky A comparison of clinical and ultrasonic estimation of fetal weightObstet Gynecol199891221270029-7844Ovid Technologies (Wolters Kluwer Health)

24 

F Zayed A Abu-Heija A comparison between ultrasound and clinical methods for predicting fetal weightJ Obstet Gynaecol1999192159610144-3615, 1364-6893Informa UK Limited

25 

S P Chauhan C A Sullivan T C Lutton E F Magann J C Morrison Parous patients’ estimate of birth weight in postterm pregnancyJ Perinatol19951531924

26 

Jonathan D. Baum Debra Gussman John C. Wirth Clinical and patient estimation of fetal weight vs. ultrasound estimationObstet Gynecol Surv20025755890029-7828Ovid Technologies (Wolters Kluwer Health)

27 

David A. Sacks Wansu Chen Estimating Fetal Weight in the Management of MacrosomiaObstetrical & Gynecological Survey2000552292390029-7828Ovid Technologies (Wolters Kluwer Health)10.1097/00006254-200004000-00022https://dx.doi.org/10.1097/00006254-200004000-00022

28 

Gerard G. Nahum Harold Stanislaw Ultrasonographic prediction of term birth weight: How accurate is it?Am J Obstet Gynecol20031882566740002-9378Elsevier BV

29 

S Ramon R Urquhart M Yusof Clinical versus ultrasound estimation of fetal weightAust N Z J Obstet Gynaecol19923231969

30 

A S Shittu K Oluwafemi E O Orji N O Mkinde S O Ogunniyi O O Ayoola Clinical versus sonographic estimation of fetal weight in Southwest NigeriaJ Health Popul Nutr2007251423

31 

Syeda Ayesha Siddiqua Deepthi Aarathi Bharath Comparative study of various methods of fetal weight estimation at term pregnancyJ Med Sci Clin Res2014210273744

32 

A Bhandaryamritha J Pinto Patrie P Shettyashwin Comparative study of various methods of fetal weight estimation at term pregnancyJ Obstet Gynecol Ind2004543369

33 

Z Pravin S Shafiuddin M A Uddin F Begum Symphysio fundal height (SFH) measurement as a predictor of birth weightFaridpur Med Coll J201272548

34 

F O Dare A S Ademowore O O Ifaturoti A Nganwuchu The value of symphysio-fundal height/abdominal girth measurements in predicting fetal weightInt J Gynaecol Obstet199031324380020-7292Wiley

35 

Anshumala Joshi Om Biju Panta Basanta Sharma Estimated fetal weight: Comparison of clinical versus ultrasound estimateJ Nepal Health Res Council2017155151727-5482, 1999-6217Nepal Journals Online (JOL)

36 

S P Chauhan N W Hendrix E F Magann J C Morrison S P Kenney L D Devoe Limitations of clinical and sonographic estimates of birth weight: experience with 1034 parturientsObstet Gynecol199891717

37 

J Piper E Xenakis M McFarland B D Elliot M D Berkus O Larger Do growth-retarded premature infants have different rates of perinatal morbidity and mortality than appropriately grown premature infants?Obstet Gynecol1996872169740029-7844Ovid Technologies (Wolters Kluwer Health)

38 

R Tiwari M Sood Comparative study of various methods of fetal weight estimation at term pregnancyJ Obstet Gynecol India19893927986

39 

N W Hendrix C S Grady S P Chauhan Clinical vs. sonographic estimate of birth weight in term parturients. A randomized clinical trialJ Reprod Med20004531722

40 

W J Watson D Stevens S Welter D Day Observations on the sonographic measurement of cervical length and the risk of premature birthJ Matern Fetal Med19998179



jats-html.xsl


This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.

Article type

Original Article


Article page

147-152


Authors Details

Kashish Sehrawat, Tushar Madhav Panchanadikar


Article Metrics


View Article As

 


Downlaod Files